Cableaway's Trench Duct / In Floor Duct is a cost-effective way of distributing power, data and audio-visual cables under your selected floor finish. Manufactured in a standard 2.4m length with a choice of widths, heights and lid finishes, it keeps floors free of trailing cables while giving easy access to services for future upgrades and maintenance.

TECHNICAL SPECIFICATIONS

Type Trench Duct / In-Floor Duct (2.4m standard length)
Body Material Steel, manufactured to size
Lid Thickness 5mm
Channel Configuration 2 or 3 channel
Reference Under Floor Trunking
Brand Cableaway

AVAILABLE SIZES

  • 38mm x 100mm x 2.4m
  • 38mm x 150mm x 2.4m
  • 50mm x 150mm x 2.4m
  • 50mm x 225mm x 2.4m
  • 40mm x 300mm x 2.4m
  • Custom widths and heights available on request (standard length 2.4m)

AVAILABLE LID FINISHES

  • Galvanised Steel
  • Aluminium Chequer Plate
  • Stainless Steel
  • Stainless Steel Chequer Plate
  • Brass
  • Perspex / Acrylic
  • Custom lid types available on request

KEY FEATURES

  • Cost-effective, clean routing of power, data and AV cables under any floor finish
  • Manufactured in a standard 2.4m length, with custom widths and heights to suit individual project requirements
  • 2 or 3 channel configurations available for segregating services
  • Wide choice of lid finishes for exposed sections, from galvanised steel to brass and acrylic
  • Keeps floors free of trailing cables, reducing trip hazards
  • Simplifies future upgrades, reconfiguration and maintenance

TYPICAL APPLICATIONS

  • Offices and open-plan workstations
  • Retail stores and showrooms
  • Schools and educational facilities
  • Train stations, ferry wharves and transport hubs
  • Boardrooms and meeting spaces
  • Commercial and institutional buildings

INSTALLATION

Recommended Installer Qualified electrician, builder or licensed trade contractor, depending on the services being routed
Fit-Out Duct body set into the floor prior to the final floor finish; lid fitted flush or left exposed as required