Cable Tray & Covers

Cable Tray & Covers

Active filters

  • Unex perforated cable tray 60x75 in U23X

    Insulating cable tray according to IEC 61537: 2006 (The values indicated...
    View Product
    Insulating cable tray according to IEC 61537: 2006 (The values indicated according to IEC 61537: 2006 have been tested under its European implementation EN 61537:2007. For support, protection and conduction of cables. Good performance outdoor, to corrosion and to chemical agents (ISO/TR 10358, DIN8061). Designed to support full load. Unex insulating cable tray with cover, by complying with the European Standard EN 50085-2-1, is considered a protecting enclosure (trunking). Impact test for trunkings: IK10 (with cover fixing). Safety: electrical; mechanical (protection against impacts 5J acc. IEC 61537; designed to work at 100% cable capacity) and in front of fire (glow-wire test at 960 Deg C; non-flame propagator). Easy and quick mounting. No burrs at cutting. Insulating material. Length: 3m. Colour: grey RAL7035.
  • Unex cover 200mm in U23X

    To cover cable trays. Insulating material. Colour: grey RAL7035. Snap-shut...
    View Product
    To cover cable trays. Insulating material. Colour: grey RAL7035. Snap-shut cover, no need for screws. IK10 protection degree with Unex cover fixing Art. no. 66845 (h. 60mm) or Art. no. 66855 (h. 100mm).
  • Unex divider for cable tray 60mm in U23X

    To separate circuits. Use 2 screws per meter. Colour: grey RAL7035....
    View Product
    To separate circuits. Use 2 screws per meter. Colour: grey RAL7035. Insulating material. Safe, easy and quick mounting.
  • Unex junction 60mm in U23X

    To join cable tray lengths. 2 bolts Art. no. 66832 are included. In areas...
    View Product
    To join cable tray lengths. 2 bolts Art. no. 66832 are included. In areas submitted to temperature changes (i. e. outdoor applications), the use of junctions is recommended in order to avoid possible warping. Colour: grey RAL7035. Insulating material. Very strong. Absorbing expansion.
  • Unex non perforated cable tray 60x75 in U23X

    Insulating cable tray according to IEC 61537: 2006 (The values indicated...
    View Product
    Insulating cable tray according to IEC 61537: 2006 (The values indicated according to IEC 61537: 2006 have been tested under its European implementation EN 61537:2007. For support, protection and conduction of cables. Good performance outdoor, to corrosion and to chemical agents (ISO/TR 10358, DIN8061). Designed to support full load. Unex insulating cable tray with cover, by complying with the European Standard EN 50085-2-1, is considered a protecting enclosure (trunking). Impact test for trunkings: IK10 (with cover fixing). Safety: electrical; mechanical (protection against impacts 5J acc. IEC 61537; designed to work at 100% cable capacity) and in front of fire (glow-wire test at 960 Deg C; non-flame propagator). Easy and quick mounting. No burrs at cutting. Insulating material. Length: 3m. Colour: grey RAL7035.
  • Unex perforated cable tray 60x100 in U23X

    Insulating cable tray according to IEC 61537: 2006 (The values indicated...
    View Product
    Insulating cable tray according to IEC 61537: 2006 (The values indicated according to IEC 61537: 2006 have been tested under its European implementation EN 61537:2007. For support, protection and conduction of cables. Good performance outdoor, to corrosion and to chemical agents (ISO/TR 10358, DIN8061). Designed to support full load. Unex insulating cable tray with cover, by complying with the European Standard EN 50085-2-1, is considered a protecting enclosure (trunking). Impact test for trunkings: IK10 (with cover fixing). Safety: electrical; mechanical (protection against impacts 10J acc. IEC 61537; designed to work at 100% cable capacity) and in front of fire (glow-wire test at 960 Deg C; non-flame propagator). Easy and quick mounting. No burrs at cutting. Insulating material. Length: 3m. Colour: grey RAL7035.
  • Unex cover 300mm in U23X

    To cover cable trays. Insulating material. Colour: grey RAL7035. Snap-shut...
    View Product
    To cover cable trays. Insulating material. Colour: grey RAL7035. Snap-shut cover, no need for screws. IK10 protection degree with Unex cover fixing Art. no. 66845 (h. 60mm) or Art. no. 66855 (h. 100mm).
  • Unex divider for cable tray 100mm in U23X

    To separate circuits. Use 2 screws (66839-A2 / 66839-A4) per meter. Colour:...
    View Product
    To separate circuits. Use 2 screws (66839-A2 / 66839-A4) per meter. Colour: grey RAL7035. Insulating material. Safe, easy and quick mounting.
  • Unex junction 100mm in U23X

    To join cable tray lengths. 2 bolts Art. no. 66832 are included. In areas...
    View Product
    To join cable tray lengths. 2 bolts Art. no. 66832 are included. In areas submitted to temperature changes (i. e. outdoor applications), the use of junctions is recommended in order to avoid possible warping. Colour: grey RAL7035. Insulating material. Very strong. Absorbing expansions.
  • Unex non perforated cable tray 60x100 in U23X

    Insulating cable tray according to IEC 61537: 2006 (The values indicated...
    View Product
    Insulating cable tray according to IEC 61537: 2006 (The values indicated according to IEC 61537: 2006 have been tested under its European implementation EN 61537:2007. For support, protection and conduction of cables. Good performance outdoor, to corrosion and to chemical agents (ISO/TR 10358, DIN8061). Designed to support full load. Unex insulating cable tray with cover, by complying with the European Standard EN 50085-2-1, is considered a protecting enclosure (trunking). Impact test for trunkings: IK10 (with cover fixing). Safety: electrical; mechanical (protection against impacts 10J acc. IEC 61537; designed to work at 100% cable capacity) and in front of fire (glow-wire test at 960 Deg C; non-flame propagator). Easy and quick mounting. No burrs at cutting. Insulating material. Length: 3m. Colour: grey RAL7035.
  • Unex perforated cable tray 60x150 in U23X

    Insulating cable tray according to IEC 61537: 2006 (The values indicated...
    View Product
    Insulating cable tray according to IEC 61537: 2006 (The values indicated according to IEC 61537: 2006 have been tested under its European implementation EN 61537:2007. For support, protection and conduction of cables. Good performance outdoor, to corrosion and to chemical agents (ISO/TR 10358, DIN8061). Designed to support full load. Unex insulating cable tray with cover, by complying with the European Standard EN 50085-2-1, is considered a protecting enclosure (trunking). Impact test for trunkings: IK10 (with cover fixing). Safety: electrical; mechanical (protection against impacts 20J acc. IEC 61537; designed to work at 100% cable capacity) and in front of fire (glow-wire test at 960 Deg C; non-flame propagator). Easy and quick mounting. No burrs at cutting. Insulating material. Length: 3m. Colour: grey RAL7035.
  • Unex cover 400mm in U23X

    To cover cable trays. Insulating material. Colour: grey RAL7035. Snap-shut...
    View Product